JEOL SpiralTOF™

This SpiralTOF™ is a special MALDI-Time-of-Flight mass spectrometer. Its patented spiral ion optics provides a 17 m flight path in a very compact format. Therefore, the SpiralTOF™ sets new standards for performance and mass resolution. It is a must-have instrument for demanding analytical tasks in all fields of natural science research, such as biochemistry, material science, and polymer research.

The SpiralTOF™ is available in two different configurations. The standard MALDI-TOF MS comes with an additional linear TOF unit. It can optionally be combined with a TOF-TOF unit. This way you get exactly the right instrument to meet your requirements.

The unique ion optics of the SpiralTOF™, which was developed by JEOL, allows flight distances of 17 m. For this application, the ions circulate up to 8 times in the spiral design. During this operation, the ion packages are refocused during each circulation. This ensures a resolution above 75,000 (FWHM) over a very large mass range, even for extremely long flight paths.

Additional information can be found here.

Specifications


SpiralTOF

SpiralTOF
TOF-TOF mode

SpiralTOF
Linear TOF mode

Mass resolving power

>75,000(FWHM)*1

>2,000(FWHM)

>2,000(FWHM)*2

Mass accuracy
(internal calibration)

< 1ppm(average error)

-

< 50ppm(peptide region)

Mass accuracy
(external calibration)

< 10ppm(average error)

-

-

Sensitivity*3

< 500 amol

< 5 fmol

< 500 amol

Mass range

m/z 4-30,000

±0.1 Da

m/z 4-500,000

Precursor ion selectivity*4

-

> 2,500

-

Precursor ion selectivity range

-

m/z 100-4,000

-

*1 Positive ion detection mode: ACTH fragment 1-17[M+H]+: m/z 2093.1 mass resolving power
*2 Angiotensin Ⅰ [M+H]+: m/z 1296.7 mass resolving power
*3 Angiotensin Ⅱ [M+H]+: m/z 1046.5 sensitivity
*4 Selection of mono-isotopic ions is possible at ACTH fragment 18-39[M+H]+

Please note:

Subject to technical changes; errors excepted. All brand names that appear in the text are registered trademarks of the manufacturers.

Contact Form

We are happy to answer your questions at no charge and free of obligation and can offer consulting on upcoming projects. Please use the following contact form (* = mandatory field) for your questions.

Choose Contact type*

Your Contact details*



News from JEOL


Message to JEOL

Disclosure of personal data to third parties

This website uses services that collect personal data in order to provide social media features and to analyse our traffic. These services include Google Maps (for the display of our location) and Google Analytics (for local website analysis). These integrated services might merge the personal data with further data. Further information on the used cookies and withdrawal can be found in our data privacy statement.
Your consent is voluntary, not necessary for using the website and can be withdrawn anytime.
You can accept or decline the transfer and processing of data by the following services.

I have read and understood the notes on privacy. I agree to the transfer and storage of my data according to the data privacy statement. I know that I have the right to withdraw this consent at any time without giving any reason, without affecting the lawfulness of the data processed after my consent and until withdrawal.